Wine Refrigeration Diagnostics
Fisher & Paykel Wine Refrigeration
Fisher & Paykel Wine Refrigeration
Error Codes
Meanings, severity levels, safe checks you can perform, and when to call a technician.
Enter the code shown on your wine refrigeration display
Is it safe to keep using it?
Depends on code severity. Low/Medium codes often allow continued use, High severity requires immediate stop.
Can error codes be reset?
Some codes clear after power cycle. Persistent codes indicate underlying issues needing repair.
When should I stop using it?
Stop immediately for water leak codes, burning smell, or any High severity error.
Error Code Directory
Click any code for detailed troubleshooting steps
Low
Medium
High
Code
Meaning
Severity
Common Symptom
DR
Door open alarm
Low
The panel shows DR and an audible alarm sounds after the door has been open for approximately 60 seconds.
View
E3
Defrost system fault
Medium
The panel shows E3 and zone temperatures slowly rise over days as the evaporator coil becomes encased in ice, reducing heat exchange efficiency.
View
E5
Control panel comm timeout
Low
The display shows E5 and button presses on the control panel produce no response.
View
F1
Upper zone sensor fault
High
The digital panel shows F1 continuously or flashes it alternately with the current zone temperature.
View
F2
Lower zone sensor fault
High
The panel shows F2 steadily or alternates the code with the lower zone temperature reading.
View
F3
Zone communication fault
High
The control panel shows F3 and one zone stops responding to temperature or fan commands from the master controller.
View
F5
Evaporator fan fault
Medium
The panel shows F5 and may also trigger a high-temperature alarm in the affected zone if cooling suffers significantly.
View
F6
Humidity sensor fault
Medium
The panel displays F6 and the humidity reading may show dashes or a fixed incorrect value.
View
F7
Condenser fan fault
Medium
The panel shows F7, often accompanied by a rising zone temperature as condenser heat rejection is impaired.
View
F8
Inverter / power module fault
High
The panel shows F8 and neither zone is maintaining temperature. The compressor may be silent or attempt to start and shut down immediately.
View
F9
LED lighting fault
Low
The panel shows F9 and interior LED lighting is partially or fully non-functional.
View
HI
High temperature alarm
Medium
The panel alternates between the current zone temperature and HI, accompanied by a repeating alarm tone.
View
LO
Low temperature alarm
Medium
The display alternates between LO and the current zone temperature, accompanied by an intermittent beeping alarm.
View